Fronius Primo Gen24 3.6 Plus Inverter

Compare

$2,179

The Fronius Primo Gen24 3.6 Plus inverter offers an emergency power solution even for three-phase consumption.
 
The Fronius GEN24 Plus single-phase hybrid inverter is the ideal heart for private photovoltaic installations. Thanks to the “PV Point”, it offers a basic integrated emergency power supply, or even a complete emergency power solution if a storage battery is connected.
The use of a storage battery enables energy self-sufficiency in terms of electricity, heating, cooling and electric mobility. With the “Full Backup” option, the Fronius GEN24 Plus offers an emergency power solution even for three-phase consumers, such as heat pumps, and thanks to Multi Flow Technology it even allows parallel power flows in the system in emergency mode.
 
Data Sheet

PRIMO GEN24 PLUS

Input Data

Models
3.0
3.6
4.0

Number of MPP followers
 
2

DC input voltage range (Udc min – Udc max)
V
65-600

Rated input voltage (Udc,r)
V
400

Commissioning voltage (start Udc)
V
80

MPP voltage range
V
65 – 530
65 – 530
65 – 530

 
 
MPPT1
MPPT2
MPPT1
MPPT2
MPPT1
MPPT2

Max input current per MPPT (Idc max.)
A
22
12
22
12
22
12

Maximum input current per MPPT (Idc max)
A
36 
19
36
19
36
19

Number of DC entries in the module field
 
2
2
2

 
 
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total

Max DC power
W
3110
3810
4140

Max PV generator output
Wpico
3750
3110
4500
4600
3810
5520
5000
4140
6000

 
 

Output Data

Models
3.0
3.6
4.0

Rated AC power (Pac,r)
W
3000
3680
4000

Apparent power
VA
3000
3680
4000

Max output power
VA
3000
3680
4000

 
 
220 VCA
230 VCA
220VCA
230 VCA
220VCA
VCA

AC output current nom. (@ 220 / 230V)
A
13,6
13
16,7
16
18,2
17,4

Grid coupling (Uac,r)
V
1~ NPE 220/230 (+20 %/-30 %)

Frequency (frequency range fmin – fmax)
Hz
50/60 (45 – 65)

Nonlinear distortion coefficient
%
< 2  Power factor (cos φac,r)   0,8 - 1 ind. / cap   Models 3.0 3.6 4.0 PV Point Output Data Rated Output Power PV Point VA 3000 3600 4000 Coupling to the PV Point network V 1~ NPE 220/230 Transition time Seg. < 35     Models 3.0 3.6 4.0 Output Data Full Backup2 rated output power "Full Backup" VA 3000 3600 4000 Coupling to the grid "Full Backup V 1~ NPE 220/230 Transition time Seg. < 35     Models 3.0 3.6 4.0 Battery Connection Number of DC inputs   1 Max input current (Idc max.) A 22 DC input voltage range (Udc min - Udc max)3 V 150-455 Battery DC connection technology   Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-) Max DC input/output power 4 W 3110 3810 4140 Max load power with AC4 coupling W 3000 3680 4000 Compatible Batteries 5    BYD Battery-Box Premium HVS/HVM y LG RESU FLEX6 Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021 The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are required for network switching. More detailed information can be found in the instruction manual. The inverter's AC derating occurs with a DC battery input voltage of 419.7V and higher. Depending on the connected battery. Depending on country-specific certification and availability 6 Except BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1 and LG RESU FLEX 17.2 Models 3.0 3.6 4.0 General data Dimensions (height × width × depth) mm 530 X 474 X165 Weight (inverter / with packaging) kg 15,4/19 15,4/19 15,4/19 protection type   IP66 protection class   1 nocturnal consumption W < 10 Overvoltage category (DC/AC)7   2/3 investor concept   without transformer refrigeration   Active Ventilation Technology Facility   Indoor and outdoor installation Ambient temperature range ºC -40a +60 Permissible air humidity % 0-100 noise emission dB (A) <42 Max altitude M 4000 DC PV connection technology   Quick connectors by pressure of 2.5-10 mm² (4 units CC+ and 4 units CC-) AC connection technology   3-pole AC push-in quick connector 2.5-10 mm² 3-pole push-in quick connector for emergency power 1.5-10 mm² PE screw terminals (2 pieces 2.5-16 mm² and 3 pieces 2.5-10mm²) Certificates and compliance 8   IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 y 16150, IEC 62116, IEC61727, G98/99 Emergency Power Features   "PV Point" o "Full Backup" Country of manufacture   Austria Life Cycle Analysis   According to ÖNORM EN ISO 14040 and 14044 (verified by staff of the Fraunhofer IZM Institute)   Models 3.0 3.6 4.0 Performance Max performance % 97,6 97,6 97,6 European performance (ηEU) % 96,8 97,0 97,1 MPP Fitting Performance % >99,9
>99,9
>99,9

 

Models
3.0
3.6
4.0

Safety equipment

DC insulation measurement
Integrated

Overload behavior
Travel to duty point, power limitation

DC disconnector
Integrated

Reverse polarity protection
Integrated

 

Models
3.0
3.6
4.0

interfaces

WLAN/2 × Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)

6 digital inputs
6 digital inputs/outputs

Wave control receiver interface, power management

Emergency stop (WSD)
Integrated

Datalogger and web server
Integrated

2 × RS485
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot

Category: