5.0K Hybrid Network Inverter – FOX ESS H1 is designed to provide maximum resistance, it also has components of the highest quality.
FOX-ESS inverters incorporate a unique cooling fin and heat sink design. It is integrated inside the inverter casing, guaranteeing direct contact with the heat generating components. FOX-ESS uses a star design that allows to enlarge the contact surface and therefore increases the cooling capacity.
Fox-ESS inverters are designed for maximum performance, efficiency, reliability, and service life.
The quality of the components used will have a direct impact on the lifespan of an inverter. That’s why Fox-ESS only uses the highest quality components from the world’s leading manufacturers.
The H series are inverters that have two MPPTs to which a string can be connected for each MPPT. This will allow further optimization of production and configurations with different orientations.
This, together with the wide range of installed power of the panels (DC – Direct Current), will allow the maximum output power (AC – Alternating Current) to be available for a greater number of hours.
With the FOX-ESS hybrid inverters, the user will be able to have a storage system to have accumulated energy to further optimize consumption and achieve more savings on the electricity bill. FOS-ESS has its own storage system for high voltage Lithium.
FOX-ESS Lithium batteries can be arranged in series allowing up to 20.8 Kwh of storage.
Of the FOX-ESS investors we can highlight:
HIGH EFFICIENCY.- Maximum efficiency between 97.4% (single-phase) and 98.2% (three-phase)
LOW START-UP VOLTAGE.- Allows a wider generation range
IP65.- For indoor and outdoor mounting. Allows more flexibility for installation.
UPGRADABLE.- Fully optimized to upgrade to FOX-ESS battery storage systems
REMOTE MONITORING.- Monitor the system remotely through a web portal or an app (available for IOS, Android and Huawey)
SECURITY.- Enhanced security features using advanced protections for Hardware and Software.
Data Sheet
MODEL
H1-3.0-E
H1-3.7-E
H1-4.6-E
H1-5.0-E
H1-6.0-E
AC1-3.0-E
AC1-3.7-E
AC1-4.6-E
AC1-5.0-E
AC1-6.0-E
PV INPUT (FOR HYBRID ONLY)
Maximum Input Power [W]
3900
4680
5980
6500
7800
Maximum Input Voltage [V]
600
Input Start Voltage [V]
75
Rated Input Voltage [V]
360
MPPT Operating Voltage Range [V]
80 ~ 550
Maximum Input Current [A]
13,5/13,5
Maximum Short Circuit Current [A]
15/15
Number of Independent MPP Trackers
2
Number of Strings per MPP Tracker
1
BATTERY CONNECTION
Battery Type
Batería de LiTIo (LFP)
Battery Voltage [V]
85 ~ 450
Maximum Charge / Discharge current [A]
40
Communication interface
CAN (Inverter Communication), RS485 (BMS Update)
AC Input and Output (GRID)
Maximum AC Input Power [VA]
7000
7680
9600
10000
12000
Maximum AC Input Current (per phase) [A]
31,8
34,9
43,6
45,5
54,5
Rated Output Power [W]
3000
3680
4600
5000
6000
Maximum Apparent Output Power [VA]
3300
4048
5060
5500
6600
Rated Output Current (per phase) [A]
13,0
16,0
20,0
21,7
26,1
Maximum Output Current [A]
14,3
17,6
22,0
23,9
28,7
Nominal Grid Voltage [V]
220/230/240
Nominal Grid Frequency [Hz]
50/60
Power Factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
THDi [%]
<3 @ rated power
EPS OUTPUT (WITH BATTERY)
Maximum Apparent Output Power [VA]
5000
5000
6000
6000
6000
Maximum Apparent Output Power (60 s) (VA)
6000
6000
7200
7200
7200
Maximum Current(per phase)[A]
21,7
21,7
26,1
26,1
26,1
Rated Output Voltage [V]
220/230/240
Rated output frequency [Hz]
50/60
Power Factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
THDv (Linear load) [%]
< 2 @ rated power
Switching time [ms]
<20
EFFICIENCY
European efficiency [%]
97,00
Maximum Efficiency [%]
97,80
Maximum Battery Charging Efficiency
98,50
(PV to BAT) (Full Charge) [%]
Maximum Battery Discharge Efficiency
97,00
(BAT to AC) (full charge) [%]
PROTECTION
Insulation Monitoring
Sí
Residual Current Monitoring
Sí
DC Reverse Polarity Protection
Sí
Protection against the isolated island effect
Sí
short circuit protection
Sí
AC Overcurrent / Overvoltage Protection
Sí
Interruptor de DC
Sí
SPD
DC: Type II, / AC: Type III
GENERAL DATA
Dimensions (WxHxD) [mm]
430*410*178
Weight [kg]
23
Facility
wall
topology
without transformer
cooling method
NaturaL
Sound Emission [dB]
35
Maximum Operating Altitude [m]
2000
Operating Temperature Range [°C]
-25 ~ 60
Humidity (No Condensation) [%]
0 ~ 100
Protection Level
IP65
Consumption in Standby Mode [W]
<10
Monitoring Module
WiFi, LAN, 4G, GPRS ( Optional )
Communication
2 * RS485, DRM, Ripple Control, USB
Screen
LCD, Applications, Websites
STANDARD COMPLIANCE (MORE AVAILABLE UPON REQUEST)
Security
EN 62109-1, EN 62109-2
EMC
EN 61000-6-2, EN 61000-6-3
Grid Regulation
EN50549-1, C10 / 11, VDE-AR-N 4105, G98, G99, CEI 0-21, NRS 097-2-1, AS / NZS 4777.2