Fronius Primo Gen24 4.6 Plus Inverter

Compare

$2,419

Fronius Primo Gen24 4.6 Plus inverter produces its own energy in a flexible and sustainable way.
 
Ready for the private energy transition: As the heart of the private photovoltaic system, our Fronius GEN24 Plus hybrid inverter enables households to produce their own energy in a flexible, sustainable and profitable way. In addition, the use of a storage battery enables complete energy self-sufficiency in terms of electricity, heating, cooling and electric mobility.
The Fronius GEN24 Plus has an integrated emergency basic power supply system (“PV Point”), which can be optionally completed with a complete system (“Full Backup”) connected to a storage battery.
EMERGENCY POWER FOR ANY SITUATION
The power supply must be safe. To do this, the Fronius GEN24 Plus offers an integrated basic emergency power supply (“PV Point”), a socket via which emergency power is supplied to connected devices as long as the sun shines or there is sufficient battery power.
Its “Full Backup” option protects the energy supply of the entire home in a totally automatic and reliable way, and it is suitable for large and three-phase consumption, such as heat pumps.
LONG USEFUL LIFE
Thanks to active ventilation, the Fronius GEN24 Plus offers more flexibility in terms of configuration and mounting right from the planning phase. In addition, the operating costs are reduced, since, if maintenance is required, it is minimal. The active ventilation system prolongs the useful life and offers additional performance.
VERSATILITY INCLUDED
More control for more power. Our inverters save time and costs sustainably thanks to energy management functions. Intelligent design and software allow for fast and flexible installation, as well as optimal performance, even when the solar modules are shaded.
At the same time, the integrated active ventilation extends the service life and thus secures your investment.
Data Sheet

PRIMO GEN24 PLUS

Input Data

Models
4.6
5.0
6.0

Number of MPP followers
 
2

DC input voltage range (Udc min – Udc max)
V
65-600

Rated input voltage (Udc,r)
V
400

Commissioning voltage (start Udc)
V
80

MPP voltage range
V
65 – 530
65 – 530
65 – 530

 
 
MPPT1
MPPT2
MPPT1
MPPT2
MPPT1
MPPT2

Max input current per MPPT (Idc max.)
A
22
12
22
12
22
12

Maximum input current per MPPT (Idc max)
A
36 
19
36
19
36
19

Number of DC entries in the module field
 
2
2
2

 
 
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total

Max DC power
W
4750
5170
6200

Max PV generator output
Wpico
5750
4750
6900
6250
5170
7500
7500
5760
9000

 
 

Output Data

Models
4.6
5.0
6.0

Rated AC power (Pac,r)
W
4600
5000
6000

Apparent power
VA
4600
5000
6000

Max output power
VA
4600
5000
6000

 
 
220 VCA
230 VCA
220VCA
230 VCA
220VCA
VCA

AC output current nom. (@ 220 / 230V)
A
20,9
20
22,7
21,7
27,3
26,1

Grid coupling (Uac,r)
V
1~ NPE 220/230 (+20 %/-30 %)

Frequency (frequency range fmin – fmax)
Hz
50/60 (45 – 65)

Nonlinear distortion coefficient
%
< 2  Power factor (cos φac,r)   0,8 - 1 ind. / cap   Models 4.6 5.0 6.0 PV Point Output Data Rated Output Power PV Point VA 3000 3600 4000 Coupling to the PV Point network V 1~ NPE 220/230 Transition time Seg. < 35     Models 4.6 5.0 6.0 Output Data Full Backup2 rated output power "Full Backup" VA 4600 5000 6000 Coupling to the grid "Full Backup V 1~ NPE 220/230 Transition time Seg. < 20     Models 4.6 5.0 6.0 Battery Connection Number of DC inputs   1 Max input current (Idc max.) A 22 DC input voltage range (Udc min - Udc max)3 V 150-455 Battery DC connection technology   Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-) Max DC input/output power 4 W 4750 5170 6200 Max load power with AC4 coupling W 4600 5000 000 Compatible Batteries 5    BYD Battery-Box Premium HVS/HVM y LG RESU FLEX6     Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021 The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are required for network switching. More detailed information can be found in the instruction manual. The inverter's AC derating occurs with a DC battery input voltage of 419.7V and higher. Depending on the connected battery. Depending on country-specific certification and availability 6 Except BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1 and LG RESU FLEX 17.2 Models 4.6 5.0 6.0 General data Dimensions (height × width × depth) mm 530 X 474 X165 Weight (inverter / with packaging) kg 15,4/19 15,4/19 15,4/19 protection type   IP66 protection class   1 nocturnal consumption W < 10 Overvoltage category (DC/AC)7   2/3 investor concept   without transformer refrigeration   Active Ventilation Technology Facility   Indoor and outdoor installation Ambient temperature range ºC -40a +60 Permissible air humidity % 0-100 noise emission dB (A) <42 Max altitude M 4000 DC PV connection technology   Quick connectors by pressure of 2.5-10 mm² (4 units CC+ and 4 units CC-) AC connection technology   3-pole AC push-in quick connector 2.5-10 mm² 3-pole push-in quick connector for emergency power 1.5-10 mm² PE screw terminals (2 pieces 2.5-16 mm² and 3 pieces 2.5-10mm²) Certificates and compliance 8   IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 y 16150, IEC 62116, IEC61727, G98/99 Emergency Power Features   "PV Point" o "Full Backup" Country of manufacture   Austria Life Cycle Analysis   According to ÖNORM EN ISO 14040 and 14044 (verified by staff of the Fraunhofer IZM Institute)   Models 3.0 3.6 4.0 Performance Max performance % 97,6 97,6 97,6 European performance (ηEU) % 96,8 97,0 97,1 MPP Fitting Performance % >99,9
>99,9
>99,9

 

Models
4.6
5.0
6.0

Safety equipment

DC insulation measurement
Integrated

Overload behavior
Travel to duty point, power limitation

DC disconnector
Integrated

Reverse polarity protection
Integrated

 

Models
4.6
5.0
6.0

interfaces

WLAN/2 × Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)

6 digital inputs
6 digital inputs/outputs

Wave control receiver interface, power management

Emergency stop (WSD)
Integrated

Datalogger and web server
Integrated

2 × RS485
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot

7.- According to IEC 62109-1 standard. Optional DC SPD type 1+2 surge protection that can be retrofitted for two MPP trackers; available under the following article number: 4,240,313,CK