Fronius Symo 5.0-3-M WLAN/LAN/SERVER/WEB inverter superior performance residential and commercial installations.
Fronius Symo 5000W three-phase grid connection solar inverter
The Fronius Symo line of pure sine wave inverters offers superior performance for three-phase residential and commercial installations. Symo inverters stand out for using transformerless technology, internet connection via WLAN or ethernet cable without additional elements.
The robust electronics and the mechanical design of the Austrian brand make the Fronius Symo inverters the best option in terms of reliability. Designed for a long life with protection against short circuits and high temperatures, the Fronius Symo are a safe option for any solar installation that wants to operate for many years.
Data Sheet
MODELS
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
DATA INPUT
Number of MPP followers
2
Max input current (Idc max. 1 / Idc max. 21))
16 A / 16 A
Maximum short-circuit current of MPP1 / MPP2 1) (Isc pv)**
31 A / 31 A
DC input voltage range (Udc min. – Udc max.)
150 – 1000 V
Commissioning voltage (start Udc)
200 V
MPP voltage range
150 – 800 V
Number of DC inputs
2+2
Max PV generator output (Pdc max.)
10,0 kWpico
12,0 kWpico
14,0 kWpico
16,4 kWpico
OUTPUT DATA
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
Rated AC power (Pac,r)
5.000 W
6.000W
7.000W
8.200 W
Maximum power output
5.000 VA
6.000 VA
7.000VA
8.200 VA
AC output current (Iac nom.)
7,2 A
8,7 A
10,1 A
11,8 A
Grid coupling (voltage range)
3~NPE 400 V / 230 V o 3~NPE 380 V / 220 V (+20 % / -30 %)
Frequency (frequency range)
50 Hz / 60 Hz (45 – 65 Hz)
Nonlinear distortion coefficient
< 3 %
Power factor (cos φac,r
0,8 - 1 ind. / cap
GENERAL DATA
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
Dimensions (height x width x depth)
645 x 431 x 204 mm
Weight
19,9
Protection type
IP65
Protection class
1
Overvoltage category (DC / AC) 2)
2/3
nocturnal consumption
< 1 W
Investor concept
without transformer
Refrigeration
Regulated air cooling
Facility
Indoor and outdoor installation
Ambient temperature range
-25 - +60 °C
Permissible air humidity
0 - 100 %
Maximum altitude
2,000 m / 3,400 m (unrestricted / restricted voltage range)
DC connection technology
4 x DC+ and 4 x DC screw terminals 2.5 - 16mm2 3)
Main connection technology
5-pole AC screw terminals 2.5 - 16mm2 3)
Certificates and compliance
ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G83/2, UNE 206007-1, SI 4777 1), CEI 0-21 1) , NRS 097
Country of manufacture
Austria
1) According to IEC 62109-1.
2) 16 mm² without the need for connection terminals.
* Isc pv = Isc max ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.
PERFORMANCE
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
Maximum performance
98,0 %
Performance European (ηEU)
96,5 %
96,9 %
97,2 %
97,7%
MPP Fitting Performance
> 99,9 %
SAFETY EQUIPMENT
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
DC insulation measurement
YES
Overload behavior
Duty point displacement, power limitation
DC disconnector
YES
Reverse polarity protection
YES
INTERFACES
SYMO 5.0-3-M
SYMO 6.0-3-M
SYMO 7.0-3-M
SYMO 8.2-3-M
WLAN/Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs
Wave Control Receiver Interface
USB (A connector) 1)
Datalogging, inverter update via USB
2 RJ 45 connectors (RS422) 1)
Fronius SolarNet
Warning output 1)
Energy management (potential free relay output)
Datalogger and Webserver
Including
External input 1)
S0-Meter / Input interface for overvoltage protection
RS485
Modbus RTU SunSpec or meter connection
1)Also available in the light version