Fronius Symo Gen24 3.0 Plus inverter

Compare

$2,389

Fronius Symo Gen24 3.0 Plus inverter is an inverter that saves time and money with a quick installation.
 
Maximum flexibility Fronius GEN24 Plus .- As the heart of your photovoltaic installation, it allows you not only to start your personal energy transition, but also to open the door to all the possibilities and advantages of solar energy.
Emergency power for any situation Secure power supply: The Fronius GEN24 Plus allows you to choose between “PV Point” and “Full Backup”, an emergency power supply for the whole house.
Easy installation Save time and money with fast and secure installation thanks to 180° quick-locking screws, quick snap connectors and a well-designed wall mounting system.
Support and tools Endless support: Efficient Fronius solutions for plant planning, assembly and monitoring are available free of charge. This increases customer satisfaction and minimizes the need for maintenance.
Data Sheet

SYMO GEN24 PLUS

Input Data

Models
3.0
4.0
5.0

Number of MPP followers
 
2

DC input voltage range (Udc min – Udc max)
V
80-1000

Rated input voltage (Udc,r)
V
610

Commissioning voltage (start Udc)
V
80

MPP voltage range
V
80-800
80-800
80-800

 
 
MPPT1
MPPT2
MPPT1
MPPT2
MPPT1
MPPT2

Max input current per MPPT (Idc max.)
A
12,5
12,5
12,5
12,5
12,5
12,5

Maximum input current per MPPT (Idc max)
A
20 
20
20
20
20
20

Number of DC entries in the module field
 
2
1
2
1
2
1

 
 
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total

Max DC power
W
3150
4180
5200

Max PV generator output
Wpico
4500
4500
4500
6000
6000
6000
6500
6500
6500

 
 

Output Data

Models
3.0
4.0
5.0

Rated AC power (Pac,r)
W
3000
4000
5000

Apparent power
VA
3000
4000
5000

Max output power
VA
3000
4000
5000

 
 
380 VCA
400 VCA
380VCA
400 VCA
380VCA
400VCA

AC output current nom. (@ 220 / 230V)
A
4,5
4,3
6,1
5,8
7,6
7,2

Grid coupling (Uac,r)
V
3~ EN 400/230 or 3~ EN 380/220  (+20 %/-30 %)

Frequency (frequency range fmin – fmax)
Hz
50/60 (45 – 65)

Nonlinear distortion coefficient
%
< 3,5 Power factor (cos φac,r)   0,7 - 1 ind. / cap   Models 3.0 4.0 5.0 PV Point Output Data Rated Output Power PV Point VA 3000 3000 30000 Coupling to the PV Point network V 1~ NPE 220/230 Transition time Seg. < 20   Models 3.0 4.0 5.0 Battery Connection Number of DC inputs   1 Max input current (Idc max.) A 12,5 DC input voltage range (Udc min - Udc max)3 V 160-531 Battery DC connection technology   Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-) Max DC input/output power 4 W 3150 4180 5200 Max load power with AC4 coupling W 3000 4000 5000 Compatible Batteries 5    BYD Battery-Box Premium HVS/HVM 5 y LG RESU FLEX Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021 The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are needed to network switching. More detailed information can be found in the instruction manual. Depending on connected battery Depending on country specific certification and availability Except BYD Battery-Box Premium HVS 12.8 and HVM 8.3   Models 3.0 4.0 5.0 General data Dimensions (height × width × depth) mm 530 X 474 X165 Weight (inverter / with packaging) kg 15,6/19,4 15,6/19,4 15,6/19,4 protection type   IP66 protection class   1 nocturnal consumption W < 10 Overvoltage category (DC/AC)7   2/3 investor concept   without transformer refrigeration   Active Ventilation Technology Facility   Indoor and outdoor installation Ambient temperature range ºC -25 a +60 Permissible air humidity % 0-100 noise emission dB (A) <36 Max altitude M 3000 / 4000 (unlimited / restricted voltage range) DC PV connection technology   Quick connectors by pressure of 2.5-10 mm² (3 units CC+ and 3 units CC-) AC connection technology   5-pole AC quick connector 1.5-10 mm² 3-pole quick connector for emergency power 1.5-10 mm² PE screw terminals 2.5-16 mm² (5 pieces) Certificates and compliance 8   IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G98/99, R25 Emergency Power Features   "PV Point" o "Full Backup" Country of manufacture   Austria Life Cycle Analysis   According to ÖNORM EN ISO 14040 and 14044 standards (verified by the staff of the Fraunhofer IZM institute)   Models 3.0 4.0 5.0 Performance Max performance % 98,1 98,2 98,2 European performance (ηEU) % 96,7 97,2 97,5 MPP Fitting Performance % >99,9
>99,9
>99,9

 

Models
3.0
4.0
5.0

Safety equipment

DC insulation measurement
Integrated

Overload behavior
Travel to duty point, power limitation

DC disconnector
Integrated

Reverse polarity protection
Integrated

 

Models
3.0
4.0
5.0

interfaces

WLAN/2 × Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)

6 digital inputs
6 digital inputs/outputs

Wave control receiver interface, power management

Emergency stop (WSD)
Integrated

Datalogger and web server
Integrated

2 × RS485
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot

 
According to IEC 62109-1 standard. Optional DC SPD type 1+2 surge protection that can be retrofitted for two MPP trackers; available under the following article number: 4,240,313,CK