Fronius Symo Gen24 4.0 Plus inverter Save time and money with a fast and safe installation.
Easy installation Save time and money with fast and secure installation thanks to 180° quick-locking screws, quick snap connectors and a well-designed wall mounting system.
Support and tools Endless support: Efficient Fronius solutions for plant planning, assembly and monitoring are available free of charge. This increases customer satisfaction and minimizes the need for maintenance.
Maximum flexibility Fronius GEN24 Plus .- As the heart of your photovoltaic installation, it allows you not only to start your personal energy transition, but also to open the door to all the possibilities and advantages of solar energy.
Emergency power for any situation Secure power supply: The Fronius GEN24 Plus allows you to choose between “PV Point” and “Full Backup”, an emergency power supply for the whole house.
Data Sheet
SYMO GEN24 PLUS
Input Data
Models
3.0
4.0
5.0
Number of MPP followers
2
DC input voltage range (Udc min – Udc max)
V
80-1000
Rated input voltage (Udc,r)
V
610
Commissioning voltage (start Udc)
V
80
MPP voltage range
V
80-800
80-800
80-800
MPPT1
MPPT2
MPPT1
MPPT2
MPPT1
MPPT2
Max input current per MPPT (Idc max.)
A
12,5
12,5
12,5
12,5
12,5
12,5
Maximum input current per MPPT (Idc max)
A
20
20
20
20
20
20
Number of DC entries in the module field
2
1
2
1
2
1
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total
MPPT1
MPPT2
Total
Max DC power
W
3150
4180
5200
Max PV generator output
Wpico
4500
4500
4500
6000
6000
6000
6500
6500
6500
Output Data
Models
3.0
4.0
5.0
Rated AC power (Pac,r)
W
3000
4000
5000
Apparent power
VA
3000
4000
5000
Max output power
VA
3000
4000
5000
380 VCA
400 VCA
380VCA
400 VCA
380VCA
400VCA
AC output current nom. (@ 220 / 230V)
A
4,5
4,3
6,1
5,8
7,6
7,2
Grid coupling (Uac,r)
V
3~ EN 400/230 or 3~ EN 380/220 (+20 %/-30 %)
Frequency (frequency range fmin – fmax)
Hz
50/60 (45 – 65)
Nonlinear distortion coefficient
%
< 3,5
Power factor (cos φac,r)
0,7 - 1 ind. / cap
Models
3.0
4.0
5.0
PV Point Output Data
Rated Output Power PV Point
VA
3000
3000
30000
Coupling to the PV Point network
V
1~ NPE 220/230
Transition time
Seg.
< 20
Models
3.0
4.0
5.0
Battery Connection
Number of DC inputs
1
Max input current (Idc max.)
A
12,5
DC input voltage range (Udc min - Udc max)3
V
160-531
Battery DC connection technology
Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-)
Max DC input/output power 4
W
3150
4180
5200
Max load power with AC4 coupling
W
3000
4000
5000
Compatible Batteries 5
BYD Battery-Box Premium HVS/HVM 5 y LG RESU FLEX
Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021
The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are needed to network switching. More detailed information can be found in the instruction manual.
Depending on connected battery
Depending on country specific certification and availability
Except BYD Battery-Box Premium HVS 12.8 and HVM 8.3
Models
3.0
4.0
5.0
General data
Dimensions (height × width × depth)
mm
530 X 474 X165
Weight (inverter / with packaging)
kg
15,6/19,4
15,6/19,4
15,6/19,4
protection type
IP66
protection class
1
nocturnal consumption
W
< 10
Overvoltage category (DC/AC)7
2/3
investor concept
without transformer
refrigeration
Active Ventilation Technology
Facility
Indoor and outdoor installation
Ambient temperature range
ºC
-25 a +60
Permissible air humidity
%
0-100
noise emission
dB (A)
<36
Max altitude
M
3000 / 4000 (unlimited / restricted voltage range)
DC PV connection technology
Quick connectors by pressure of 2.5-10 mm² (3 units CC+ and 3 units CC-)
AC connection technology
5-pole AC quick connector 1.5-10 mm² 3-pole quick connector for emergency power 1.5-10 mm² PE screw terminals 2.5-16 mm² (5 pieces)
Certificates and compliance 8
IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G98/99, R25
Emergency Power Features
"PV Point" o "Full Backup"
Country of manufacture
Austria
Life Cycle Analysis
According to ÖNORM EN ISO 14040 and 14044 standards
(verified by the staff of the Fraunhofer IZM institute)
Models
3.0
4.0
5.0
Performance
Max performance
%
98,1
98,2
98,2
European performance (ηEU)
%
96,7
97,2
97,5
MPP Fitting Performance
%
>99,9
>99,9
>99,9
Models
3.0
4.0
5.0
Safety equipment
DC insulation measurement
Integrated
Overload behavior
Travel to duty point, power limitation
DC disconnector
Integrated
Reverse polarity protection
Integrated
Models
3.0
4.0
5.0
interfaces
WLAN/2 × Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 digital inputs
6 digital inputs/outputs
Wave control receiver interface, power management
Emergency stop (WSD)
Integrated
Datalogger and web server
Integrated
2 × RS485
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot
According to IEC 62109-1 standard. Optional DC SPD type 1+2 surge protection that can be retrofitted for two MPP trackers; available under the following article number: 4,240,313,CK