The Grid Inverter Fronius Primo 4.0 – 1 Light is the ideal equipment to meet the needs of any home.
Characteristics of the FRONIUS Primo 4.0-1 light 4kW Network Inverter
The FRONIUS Primo 4.0-1 light 4kW Grid-Connection Inverter is a single-phase, transformer-free grid-connected inverter.
Primo grid connection inverters that have the name “Light” are those that do not have the WLAN communication module installed to be able to view the inverter data over the Internet, those inverters that do not have the name “Light” do they have incorporated
Applications and features of the FRONIUS Primo 4.0-1 light 4kW Grid Connection Inverter:
The FRONIUS Primo 4.0-1 light 4kW Grid Connection Inverter is a single-phase grid connection inverter. All Primo models incorporate two MPPT and have IP65 protection, but the light variants lack Wlan communications for remote monitoring and management. It is ideal to meet the needs of any home.
Primo models have a standard internet interface via Wlan or Ethernet and easy integration with components from other manufacturers, including data manager and free connection to the solarweb portal.
It has a Meter interface that allows dynamic power management and consumption display.
The FRONIUS Primo 4.0-1 light 4kW Grid Connection Inverter is an inverter that allows us to interconnect with the electrical grid without the need for batteries, which is why this type of installation is economical and very profitable in the long term, given its low cost. Coming from a simple installation and with few electronic devices that make the system more expensive.
For a grid connection installation to work correctly, we will need a group of solar panels, previously calculated to suit the needs of each case, and a grid connection inverter, which will allow us to transform energy from the solar panels to be able to make use of it
Fronius inverters have a zero grid injection system, this means that in the event that the solar installation is producing more energy than the home or industrial building is consuming, the zero injection system will allow us to reduce at will the power of the inverter only in the event that there is an energy surplus.
In short, the functionality of zero injection systems is to reduce the power of the inverter when the energy produced is greater than the energy consumed, thus preventing it from being discharged into the general electrical network.
TECHNICAL DATA FRONIUS PRIMO
DATA IMPUT
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
Number of MPP followers
2
Max input current (Idc max 1/ Idc max 2)
12 A / 12 A
Maximum short circuit current of MPP1/MPP2 (Isc pv) *
24 A / 24 A
DC input voltage range (Udc min. – Udc max.)
80 – 1000 V
Commissioning voltage (start Udc)
80 V
MPP voltage range
80 – 800 V
Number of DC inputs
2 + 2
Max PV generator output (Pdc max.)
4,5 kWpico
5,3 kWpico
5,5 kWpico
6,0 kWpico
6,9 kWpico
OUTPUT DATA
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
Rated AC power (Pac,r)
3000W
3.500 W
3.680 W
4000W
4600W
maximum power output
3.000 VA
3.500 VA
3.680 VA
4.000 VA
4.600 VA
AC output current (Iac nom.)
13 A
15,2 A
16 A
17,4 A
20 A
Grid coupling (voltage range)
1 ~ NPE 220 V / 230 V (180 V – 270 V)
Frequency (frequency range)
50 Hz / 60 Hz (45 – 65 Hz)
Nonlinear distortion coefficient
< 3 %
Power factor (cos φac,r)
0,85 - 1 ind. / cap
GENERAL DATA
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
Dimensions (height x width x depth)
645 x 431 x 204 mm
Weight
21,5 kg
protection type
IP 65
protection class
1
Overvoltage category (DC / AC) 1)
2 / 3
nocturnal consumption
< 1 W
investor concept
without transformer
Refrigeration
Regulated air cooling
Facility
Indoor and outdoor installation
Ambient temperature range
-40 - +55 °C
Permissible air humidity
0 - 100 %
maximum altitude
4.000 m
DC connection technology
4x X+ and 4 x DC screw terminals 2.5 - 16 mm²
Main connection technology
3-pole AC screw terminals 2.5 - 16 mm²
Certificates and compliance
DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 4777-2, AS 4777-3, G98/1, G99/1, CEI 0-21, VDE AR N 4105
Country of manufacture
Austria
PERFORMANCE
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
Maximum performance
98,0 %
98,0 %
98,0 %
98,1 %
98,1 %
European Yield (ηEU)
96,1 %
96,8 %
96,8 %
97,0 %
97,0 %
MPP Fitting Performance
> 99,9 %
SAFETY EQUIPMENT
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
DC insulation measurement
Yes
Overload behavior
Duty point displacement, power limitation
DC disconnector
Yes
Reverse polarity protection
Yes
INTERFACES
PRIMO 3.0-1
PRIMO 3.5-1
PRIMO 3.6-1
PRIMO 4.0-1
PRIMO 4.6-1
WLAN / Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs
Wave Control Receiver Interface
USB (Conector A) 2)
Datalogging, inverter update via USB
2 RJ 45 connectors (RS422) 2)
Fronius Solar Net
Warning output 2)
Energy management (potential free relay output)
Datalogger and web server
Including
External input 2)
S0-Meter / Input interface for overvoltage protection
RS485
Modbus RTU SunSpec or meter connection
1) According to IEC 62109-1.
2) Also available in the light version.