FOX Hybrid Grid Inverter – ESS H1-3.0K with simple configuration and maximum round-trip efficiency.
Using solar and night energy with a innovative range of FOX AC/hybrid inverters. Composed of advanced features and compatible with our own series of high voltage batteries (FOX’s hybrid range). is an investor of upper class.
Simple Installation: Flexible configuration, plug-play configuration, built-in fuse protection.
High Voltage: Connected to high voltage batteries for maximum roundtrip efficiency.
IP65 level: Design to prolong useful life with maximum flexibility for outdoor installation.
Remote Monitoring: Monitor your system remotely through a smartphone app or web portal.
Data Sheet
MODEL
H1-3.0-E
H1-3.7-E
H1-4.6-E
H1-5.0-E
H1-6.0-E
AC1-3.0-E
AC1-3.7-E
AC1-4.6-E
AC1-5.0-E
AC1-6.0-E
PV INPUT (FOR HYBRID ONLY)
Maximum Input Power [W]
3900
4680
5980
6500
7800
Maximum Input Voltage [V]
600
Input Start Voltage [V]
75
Rated Input Voltage [V]
360
MPPT Operating Voltage Range [V]
80 ~ 550
Maximum Input Current [A]
13,5/13,5
Maximum Short Circuit Current [A]
15/15
Number of Independent MPP Trackers
2
Number of Strings per MPP Tracker
1
CONEXIÓN DE BATERÍA
Battery Type
Batería de LiTIo (LFP)
Battery Voltage [V]
85 ~ 450
Maximum Charge / Discharge current [A]
40
Communication interface
CAN (Inverter Communication), RS485 (BMS Update)
AC Input and Output (GRID)
Maximum AC Input Power [VA]
7000
7680
9600
10000
12000
Maximum AC Input Current (per phase) [A]
31,8
34,9
43,6
45,5
54,5
Rated Output Power [W]
3000
3680
4600
5000
6000
Maximum Apparent Output Power [VA]
3300
4048
5060
5500
6600
Rated Output Current (per phase) [A]
13,0
16,0
20,0
21,7
26,1
Maximum Output Current [A]
14,3
17,6
22,0
23,9
28,7
Nominal Grid Voltage [V]
220/230/240
Nominal Grid Frequency [Hz]
50/60
Power Factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
THDi [%]
<3 @ rated power
EPS OUTPUT (WITH BATTERY)
Maximum Apparent Output Power [VA]
5000
5000
6000
6000
6000
Maximum Apparent Output Power (60 s) (VA)
6000
6000
7200
7200
7200
Maximum Current(per phase)[A]
21,7
21,7
26,1
26,1
26,1
Rated Output Voltage [V]
220/230/240
Rated output frequency [Hz]
50/60
Power Factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
THDv (Linear load) [%]
< 2 @ rated power
Switching time [ms]
<20
EFFICIENCY
European efficiency [%]
97,00
Maximum Efficiency [%]
97,80
Maximum Battery Charging Efficiency
98,50
(PV to BAT) (Full Charge) [%]
Maximum Battery Discharge Efficiency
97,00
(BAT to AC) (full charge) [%]
PROTECTION
Insulation Monitoring
Sí
Residual Current Monitoring
Sí
DC Reverse Polarity Protection
Sí
Protection against the isolated island effect
Sí
short circuit protection
Sí
AC Overcurrent / Overvoltage Protection
Sí
Interruptor de DC
Sí
SPD
DC: Type II, / AC: Type III
GENERAL DATA
Dimensions (WxHxD) [mm]
430*410*178
Weight [kg]
23
Facility
wall
topology
without transformer
cooling method
NaturaL
Sound Emission [dB]
35
Maximum Operating Altitude [m]
2000
Operating Temperature Range [°C]
-25 ~ 60
Humidity (No Condensation) [%]
0 ~ 100
Protection Level
IP65
Consumption in Standby Mode [W]
<10
Monitoring Module
WiFi, LAN, 4G, GPRS ( Optional )
Communication
2 * RS485, DRM, Ripple Control, USB
Screen
LCD, Applications, Websites
STANDARD COMPLIANCE (MORE AVAILABLE UPON REQUEST)
Security
EN 62109-1, EN 62109-2
EMC
EN 61000-6-2, EN 61000-6-3
Grid Regulation
EN50549-1, C10 / 11, VDE-AR-N 4105, G98, G99, CEI 0-21, NRS 097-2-1, AS / NZS 4777.2
* More technical features available to be customized on demand.