FOX Three-Phase Inverter – ESS T6 6KW T Series only uses components of the highest quality.
The quality of the components used will have a direct impact on the lifespan of an inverter. That’s why Fox-ESS only uses the highest quality components from the world’s leading manufacturers.
Fox-ESS inverters are designed for maximum performance, efficiency, reliability, and service life.
Data Sheet
MODEL
T3
T5
T6
T8
T10
INPUT
Max. Recommended DC power [W]
4500
7500
9000
12000
15000
Max. DC Voltage [V]
1100
Nominal DC Operating Voltage [V]
600
Max. Input Current (input A/input B) [A]
12.5/12.5
Max. Short Circuit Current (input A/input B) [A]
16.25/16.25
MPPT Voltage Range [Vdc]
160-850
MPPT Voltage Range (full load) [Vdc]
160-850
210-850
250-850
330-850
410-850
Start-up Voltage [V]
180
No. of MPP Trackers
2
Strings per MPP Tracker
1+1
OUTPUT
Nominal AC Power [W]
3000
5000
6000
8000
10000
Max. Apparent AC Power [VA]
3300
5500
6600
8800
11000
Rated Grid Voltage (AC Voltage Range) [Vac]
3/N/PE, 230/400 (310-480)
Rated Grid Frequency [Hz]
50/60, ±5
Nominal AC Current [A]
4.3
7.2
8.7
11.6
14.5
Max. AC Current [A]
4.8
8.0
9.6
12.8
15.9
Displacement Power Factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
Total Harmonic Distortion (THDi, @rated output)
<3%
EFFICIENCY
MPPT Efficiency [%]
99.8%
Euro Efficiency [%]
97.8%
Max. Efficiency (@rated voltage) [%]
98.6%
PROTECTION
DC Reverse-polarity Protection:
YES
Anti-islanding Protection
YES
Insulation Monitoring:
YES
Residual Current Monitoring:
YES
AC Short Circuit Protection:
YES
AC Output Over Current Protection:
YES
AC Output Over Voltage Protection:
YES
Surge Protection:
YES
Temperature Protection:
YES
Integrated DC Switch:
Optional
STANDARD
Safety
IEC62109-1/2
EMC
IEC 61000-6-1/IEC 61000-6-2/IEC 61000-6-3/IEC61000-4-2/3/4/5/6/8
Certification
AS4777.2-2015 / VDE-AR-N 4105 /VDE0126-1-1 /G98 / G99 / EN50549-1/ CEI 0-21 IEC62116 /IEC61727 /IEC61683
GENERAL DATA
Dimensions (WxHxD) [mm]
475 x 384 x 186
NET Weight [kg]
20
Cooling Concept
Convection
Degree of Protection (according to IEC60529)
IP65
Topology
Transformerless
Over Voltage Category
III (AC side), II (PV side)
Noise [dB]
<30
Operating Temperature Range [°C]
-20…... +60°C (derating at +45°C)
Storage Temperature Range [°C]
-40…... +70°C
Altitude
3000
Humidity
0-100% (no condensation)
Self Consumption (night) [W]
<3W
Monitoring Module (optional)
RS485, WIFI (optional) / GPRS (optional)
Communication
Meter, DRM, USB update, E-stop
Display
LCD screen, Touch Key, App, Website